Hakuto科学機器 取扱製品紹介

電磁石用電源PCU Series

■ Technical description

Model (PCUM) 50-100 50-200 50-300 30-340
Nominal output current (A) 100 200 300 340
Nominal output voltage (V) 50 50 50 30
Nominal output power (W) 5000 10000 15000 10000
Line input voltage (V) +/-10% 400/3p; 47…63Hz (other on request)
Ambient temperature 0 - 40°C
Minimum efficiency (full load) (%) ≥90
Power factor (%) ≥90
Setting range (%) 1-100
Regulation mode CC or CV mode, selectable
Displays 2-line LCD display: 5 digits for current, 4 digits for voltage,
CC or CV mode, alarm message; LED indications for failures
Interface analog 0 … 10V analog interface for current & voltage measuring and setting
Interface digital RS422 digital interface for current & voltage measuring and setting, output ON/OFF with status; indication and reset of alarms; polarity indication
Ramp function Programmable di/dt ramp function
Current loop adjustment Via plug on components
DAC resolution 16 bit
ADC resolution 16 bit
Rise time (10-90%) full load Depending on load (R,L), typically 30ms
Residual voltage ripple p/p up to 10kHz 200 ... 300mV
Current deviation for +/- 10% of mains variation (full load) ≤5ppm
Current deviation for +/- 10% of load variation ≤5ppm
Current stability over 8 hours (after 1 hour of warm-up) ≤6ppm
Current deviation in temperature range (ppm/°C) ≤5ppm
Absolute current accuracy deviation 2mA 4mA 6mA 7mA
Current reproducibility deviation 5mA 10mA 15mA 17mA
MTBF (hrs) ≥100000
Input/output insulation (kV r.m.s. 1min) 2,3
Output/case insulation (kV DC 1min) 1
Cooling Air cooling (water cooled optionally)

■ Product Summary PCUM

Type Voltage
[V DC]
Current
[A]
Power
[W]
Height
[HE/U]
Rack Depth
[mm]
Weight
[kg]
Chassis Part Number
PCUM 50-100 0 .... 50 0 ... 100 5000 3 550 37 19" slide 00.270.011.01
PCUM 50-200 0 .... 50 0 ... 200 10000 6 550 55 19” slide 00.270.011.02
PCUM 50-300 0 .... 50 0 ... 300 15000 9 550 75 19” slide 00.270.011.03
PAGE TOP